ADA threshold height tops out at 1/2 inch for new construction, with any threshold over 1/4 inch requiring a bevel no steeper than 1:2. Existing or altered thresholds get a narrow exception up to 3/4 inch, provided both sides are beveled at that same 1:2 slope. These figures come directly from the 2010 ADA Standards, Section 404.2.5. The rest of this reference walks through measurement method, exceptions, and design solutions that keep water out while keeping thresholds compliant.
TL;DR:
- Thresholds in new construction must be 1/2 inch or less, with a bevel slope no steeper than 1:2 for heights over 1/4 inch.
- Existing or altered thresholds can be up to 3/4 inch if beveled on both sides at the same 1:2 slope, but this exception is limited to renovation projects.
- Accurate measurement requires checking from finished floors with carpet and padding compressed, not subfloor, to avoid compliance failures.
- Proper design and weatherproofing of low-profile thresholds are essential to prevent water intrusion and air leakage over time.
- Manufacturers’ certified tolerances and third-party water testing data ensure thresholds meet ADA height limits consistently in the field.
Table of Contents
- What the ADA Standard Actually Says About Threshold Height
- How to Measure Threshold Height Without Failing Inspection
- Balancing ADA Compliance With Weather Performance
- Design Solutions That Satisfy Both Accessibility and Drainage
- A Compliance Checklist for Spec Writers and Inspectors
- How ViewLux Documentation Supports Accessible Threshold Detailing
- Where to Find the Official Standard Text
- Get Threshold Details Right at the Fabrication Stage
- What Actually Deserves Priority Here
- Sources
- FAQ
What the ADA Standard Actually Says About Threshold Height
Section 404.2.5 of the 2010 ADA Standards governs thresholds at doorways, and the text is more specific than most spec writers realize. It doesn’t just cap the height. It also dictates how that height gets resolved into a walkable surface.
The core requirements designers need memorized:
- Maximum height, new construction: 1/2 inch (13 mm).
- Bevel trigger: any threshold exceeding 1/4 inch in height must be beveled, with the slope no steeper than 1:2 (a 1 inch rise for every 2 inches of run).
- Existing or altered threshold exception: up to 3/4 inch (19 mm), beveled on both sides at 1:2 or shallower.
- Sliding door tracks: may present additional height at the track itself, evaluated under the same bevel and change-in-level logic.
Two other sections do quiet but essential work here. Section 302 governs floor and ground surfaces generally, requiring them to be stable, firm, and slip-resistant, which matters because a threshold is technically a floor surface transition. Section 303 covers changes in level, and it’s the section that actually defines when a bump becomes a “threshold” problem versus a routine floor joint. Under 303, changes up to 1/4 inch can be vertical with no bevel at all; anything from 1/4 inch to 1/2 inch needs the 1:2 bevel; beyond 1/2 inch, you’re generally into ramp territory unless the threshold exception applies.
Code commentary from Lori Greene at Allegion confirms that ICC A117.1, the model code most jurisdictions adopt alongside the ADA, mirrors this structure almost exactly. That alignment matters for builders working across state lines. If your local code references A117.1 instead of citing ADA sections directly, the numeric limits don’t change.

How to Measure Threshold Height Without Failing Inspection
Measurement errors cause more compliance failures than actual design mistakes. Get the protocol wrong, and a threshold that looks fine on paper fails on site.
- Measure from the finished floor, not the subfloor. Inspectors check the top of the threshold against the finished interior floor surface, including tile, hardwood, or any topping layer that will be installed.
- Compress carpet fully, including the pad. When carpet is specified, the finished floor measurement assumes the carpet and pad are compressed under normal foot traffic, not resting at full pile height. A plush pad that seems negligible on the shelf can add enough thickness to push a threshold over the 1/2 inch line once compressed.
- Confirm what counts as “existing or altered.” The 3/4 inch exception applies to thresholds in existing buildings, or those being altered as part of a renovation, not new construction. New builds don’t get the exception.
- Check exterior landing conditions separately. Impervious exterior surfaces (concrete, pavers) can sit up to 4 inches below the interior finished floor without triggering ramp requirements, since that drop manages water rather than creating a walking-surface hazard.
- Watch sliding door track height. Track assemblies for sliding doors often carry their own bevel and height evaluation, since the track itself can create a change in level distinct from the threshold plate.
The most common on-site error is a superintendent measuring to the subfloor before finish materials go down, then assuming the number is final. Mock-up the finished condition before pouring or setting anything permanent.
Balancing ADA Compliance With Weather Performance
Low-profile thresholds present challenges balancing accessibility and water management, often requiring careful coordination to avoid water intrusion.
Low-profile thresholds reduce the physical barrier but also reduce the dam that keeps water out. Trade sources note that ADA-compliant low thresholds can struggle with water resistance unless the rest of the assembly compensates. That compensation usually comes down to a few features worth prioritizing during submittal review:
- Integrated weather seals suitable for the climate and exposure.
- Effective sill drainage to prevent water pooling near the threshold.
- Interlocking threshold assemblies that improve water resistance beyond gasket-only solutions.
- Flashing details that integrate the threshold with surrounding construction for water protection.
Failure modes tend to cluster around two symptoms: water intrusion at the sill corners, and air infiltration that shows up as a comfort complaint months after occupancy. Both usually trace back to a threshold detail that met the numeric ADA requirement but skipped the weatherproofing coordination that should have accompanied it. A door assembly like ViewLux’s aluminum door systems with flush, performance-rated sills addresses both concerns at once, which is exactly the kind of detail worth flagging in a submittal package.
Pro Tip: When reviewing manufacturer submittals, ask for third-party water infiltration test data at the specific threshold height and bevel configuration you’re specifying, not just the product’s general performance rating. A sill that passes AAMA water testing at 1/2 inch can behave differently at 3/4 inch with a steeper bevel.
Design Solutions That Satisfy Both Accessibility and Drainage
Meeting the numeric limit is only half the job. The other half is choosing a detail that won’t need a warranty call in year two.
- Consider raising exterior finishes to reduce vertical change at thresholds. Bringing pavers, concrete, or decking up closer to the interior finished floor height reduces the total change in level the threshold has to absorb, which often lets you use a shallower bevel or skip the exception altogether.
- Select interlocking threshold designs for improved accessibility and water control. Interlocking systems that bring the exterior surface closer to the interior finished floor outperform standard low-profile sills that depend entirely on a gasket for water control.
- Detail thresholds with continuous bevels rather than partial vertical changes for compliance and inspection clarity. A threshold that mixes a small vertical lip with a partial bevel is harder to inspect and easier to get wrong. A continuous 1:2 bevel across the full width of the opening is cleaner to detail and cleaner to verify.
- Use ramps when vertical changes exceed permitted threshold heights without applicable exceptions. Ramps must run no steeper than 1:12, and that threshold decision point is exactly where the 1/2 inch and 3/4 inch numbers stop being abstract and start dictating actual construction sequencing.
- Apply bevel slope requirements to sliding door tracks as part of threshold review. Multi-family buildings especially, where sliding doors onto balconies are common, need track details reviewed against 404.2.5 the same way a swing door threshold would be.
For builders configuring custom openings, reviewing aluminum door configuration options early in design avoids costly field changes once the threshold detail is locked into a submittal.
A Compliance Checklist for Spec Writers and Inspectors
Keep this list next to the drawings during both design review and final walkthrough.
- Confirm the measurement reference point is the finished floor, not subfloor, including carpet compressed to the pad.
- Verify bevel slope does not exceed 1:2 on any threshold over 1/4 inch, and confirm it’s continuous across the full opening width.
- Document whether the condition qualifies as “existing or altered” before applying the 3/4 inch exception. New construction does not qualify.
- Check exterior landing surface type (impervious vs. pervious) against the allowable level change for that surface.
- Record actual field measurements against the drawings and note any deviation before final sign-off.
Spec language should reference the standard directly rather than paraphrasing it loosely. A line like “Thresholds shall comply with 2010 ADA Standards Section 404.2.5, maximum 1/2 inch, beveled at 1:2 where required” gives contractors and inspectors an unambiguous checkpoint. For door hardware and component specification more broadly, a detailed door components guide helps keep submittals organized. Contractors weighing when a threshold is even necessary on a given opening can also find useful field perspective from door installation guidance written for that exact decision point.
How ViewLux Documentation Supports Accessible Threshold Detailing
Manufacturer documentation is where a lot of ADA threshold compliance either gets locked in or quietly falls apart. A product that’s rated correctly on a data sheet still needs consistent fabrication tolerances to hit the same threshold height on every unit shipped.
ViewLux’s NFRC and AAMA certifications tie directly into that consistency. Windows and doors that pass third-party performance testing carry documented tolerances, which means the threshold height specified in a submittal is the threshold height that shows up on site, not an approximation. The flush sill and threshold detail guide covers drainage geometry and fabrication tolerances relevant to teams specifying accessible openings. For overall opening dimensions and how threshold height interacts with rough-in planning, the window height reference is worth including in a submittal package alongside the manufacturer’s certified test data.
Where to Find the Official Standard Text
Start with the Access Board’s chapter on entrances, doors, and gates for the plain-language guide to Section 404. The ADA.gov 2010 Standards page hosts the legally binding text itself. For the codified federal version, the e-CFR reproduction of 36 CFR Appendix D is the citation to use in legal or contractual documents. UpCodes’ commentary on exterior thresholds and I Dig Hardware’s practitioner analysis both translate the code language into field-ready guidance.
Get Threshold Details Right at the Fabrication Stage
Threshold height failures rarely start with bad intentions. They start with a detail that looked fine on a drawing and then got value-engineered in the field, or a sill product chosen for cost before anyone confirmed its tested height matched the spec. Working with a manufacturer that documents fabrication tolerances against NFRC and AAMA testing removes that guesswork before installation day.
ViewLux Windows & Doors builds custom aluminum door systems, including arched swing configurations, with performance sills engineered to hit ADA numeric limits without sacrificing water resistance. Builders and architects specifying custom aluminum windows for luxury or multi-family projects get factory-direct pricing and documented tolerances in the same submittal package, which shortens the review cycle considerably compared to sourcing thresholds and door frames separately.
What Actually Deserves Priority Here
Most ADA threshold guidance treats the 1/2 inch and 3/4 inch numbers as the whole story. They’re not. The numbers are the easy part. What separates a compliant threshold that lasts twenty years from one that generates a warranty call in year three is the measurement discipline behind it, specifically whether anyone actually modeled the finished floor condition with carpet compressed before pouring the slab.

The conventional advice to “use the 3/4 inch exception when needed” undersells how much that exception should be a last resort, not a design default. Code commentary from Lori Greene makes this point clearly: the exception exists for genuinely constrained existing conditions, not as a convenient buffer for new work that could have hit 1/2 inch with better planning.
If you take one thing from this reference, prioritize the measurement protocol over the exception language. A threshold that’s correctly measured against the finished floor, with carpet and pad accounted for, rarely needs the exception in the first place. The teams that get burned are the ones who measured to subfloor, assumed they had margin, and found out otherwise during final inspection.
— Liran
Sources
- Guide to the ADA Accessibility Standards
- Decoded: Thresholds – I Dig Hardware (Allegion Lori Greene)
- Thresholds and Accessible Routes at Exterior Doors | UpCodes
- 36 CFR Appendix D to Part 1191 – Technical | e-CFR
FAQ
How high can a threshold be under ADA rules?
New construction thresholds must be 1/2 inch (13 mm) or less. Existing or altered thresholds may go up to 3/4 inch (19 mm) if beveled on both sides at a slope no steeper than 1:2.
What is the ADA height requirement for a threshold bevel?
Any threshold over 1/4 inch high requires a bevel with a slope no steeper than 1:2, meaning a 1 inch rise for every 2 inches of horizontal run.
What are the ADA accessibility requirements for door thresholds in 2026?
The requirements haven’t changed: the 2010 ADA Standards still govern, with a 1/2 inch maximum for new construction and a 3/4 inch exception for existing or altered thresholds with proper beveling.
Does a 32 inch door meet ADA requirements?
Door width and threshold height are separate requirements. Clear opening width requirements generally satisfy ADA door clearance rules, but the door still needs a compliant threshold at 1/2 inch or less (or 3/4 inch with beveling under the existing/altered exception) to be fully compliant.
Do sliding doors follow the same threshold height rule?
Yes. Sliding door tracks are evaluated under the same 404.2.5 height and bevel logic, though the track assembly itself can introduce a separate change-in-level that needs its own bevel review.