A condensation resistance (CR) rating tells you how well a window resists moisture forming on its interior surface. It is reported on a scale of 1 to 100, and a higher number means better resistance under the standard test conditions. The rating is optional, it is a comparison tool, and it works best when read together with the wall assembly, the climate and the way the building is humidified and heated.
TL;DR
- The NFRC CR rating measures a window’s ability to resist condensation on its interior surface.
- Scores run from 1 to 100. Higher is better, and the score is dimensionless.
- The overall product rating is the lowest of the frame, edge-of-glass and center-of-glass results.
- NFRC is moving from the original CR rating to a newer Condensation Index (CI). Both use the same standard temperatures.
- A strong rating is a guide, not a guarantee. Installation, trim, humidity and heat distribution all change real-world results.
Table of Contents
- What a condensation resistance rating measures
- Reading the 1 to 100 scale
- How the rating is determined
- CR versus Condensation Index (CI)
- How CR differs from U-factor, SHGC and VT
- Why a strong rating does not guarantee a dry window
- Using CR when you specify windows
- Our perspective
- Specify condensation-conscious aluminum windows and doors
- FAQ
- Sources
What a condensation resistance rating measures
Condensation forms when moist indoor air touches a surface colder than its dew point. On a window, the coldest areas are usually the frame, the spacer zone at the edge of the glass and, on single or poorly insulated glazing, the glass itself. The CR rating quantifies how well a complete product keeps those interior surfaces warm enough to avoid that point.
According to the U.S. Department of Energy’s Building America measure guideline on window performance, the National Fenestration Rating Council (NFRC) CR rating measures the ability of a window or door product to resist the formation of condensation on its interior surface. It is a property of the whole product: frame material, frame geometry, glass package, spacer and how they work together.
That is why two windows with the same glass can carry different CR numbers. A frame with a better thermal break, or a different edge-of-glass construction, changes how cold the interior surface becomes at the weakest point.

Where it appears on the label
The NFRC label is the standard way to compare fenestration products in the United States. Required ratings such as U-factor and solar heat gain coefficient (SHGC) sit alongside visible transmittance (VT) and air leakage. CR is different: NFRC describes it as an optional rating that manufacturers can choose to include on their labels. If a label shows no CR number, the product has not necessarily failed anything. The manufacturer simply has not published one, and you can ask for it.
For a full walkthrough of the label, see our guide to the five NFRC numbers homeowners should check.
Reading the 1 to 100 scale
NFRC states that condensation ratings are dimensionless and range from 1 to 100, with higher values indicating better performance under the specified conditions. Its Condensation Index page and the CR fact sheet say the same thing in plain terms: a higher number, better resistance.
Three points help when interpreting a score.
- It is relative, not absolute. A CR of 60 does not mean a 60% chance of condensation. The number ranks products against each other under one fixed set of conditions.
- It is not a percentage of humidity. The scale has no units. Treat it as a ranking index.
- The conditions are fixed. Every product is evaluated against the same exterior and interior temperatures, so numbers from different manufacturers can be compared fairly, provided both use the same rating method.
Because the scale is a comparison device, the useful question is rarely “Is this number good?” It is “How does this configuration compare with the others I am considering, in a building that will be this humid and this cold?”
How the rating is determined
NFRC explains that a CR rating comes from computer modeling or physical testing. The product is not given a single average. Instead, the lowest rating among the frame, edge-of-glass and center-of-glass becomes the rating for the overall product.

This “weakest link” rule matters for specifiers. A window with excellent glass but a conductive frame will score according to the frame. Upgrading only the glazing will not raise the overall number if the frame or edge is the limiting component.
The standard test conditions
The procedure, NFRC 500, is built on standardized environmental conditions: 0°F (-18°C) outside and 70°F (21°C) inside. The results use three relative humidity levels, 30%, 50% and 70%, and window surface temperatures are recorded for each level.
Those conditions are deliberately cold. They represent a stress case, which is why the rating is useful for ranking products by how they behave when the temperature difference across the window is large.
| Element | Standard condition |
|---|---|
| Exterior temperature | 0°F (-18°C) |
| Interior temperature | 70°F (21°C) |
| Relative humidity levels | 30%, 50%, 70% |
| Product rating | Lowest of frame, edge-of-glass, center-of-glass |
Source for all four rows: the NFRC CR fact sheet and its codes page.
CR versus Condensation Index (CI)
NFRC is currently transitioning from the original CR rating (NFRC 500-2017) to a newer Condensation Index (ANSI/NFRC 500-2020), according to its codes page. You may see either label while the change works through the market.
The practical differences are small for a buyer:
- Calculation. CI is calculated from a ratio involving the difference between the profile’s coldest temperature and the exterior air temperature.
- Scale. Both are dimensionless, and both run from 1 to 100 with higher values better.
- Conditions. Despite different calculation methods, both use the same standardized -18°C (0°F) exterior and 21°C (70°F) interior conditions, as the NFRC Condensation Index page explains.
The rule for comparison is simple: compare CR with CR and CI with CI. Do not rank a CR number against a CI number as if they were the same measurement, and ask the supplier which method each quoted value uses.
How CR differs from U-factor, SHGC and VT
CR is easy to confuse with the other label values. NFRC’s fact sheet separates them by function: CR targets the potential for moisture build-up, U-factor measures insulation performance, SHGC measures solar heat gain, and VT measures light transmittance. U-factor is closely related to condensation resistance, since a window that loses less heat keeps its inner surface warmer, but each rating serves a separate purpose.
In practice:
- A low U-factor helps, but does not replace a CR number, because CR reflects the coldest spot, not the area-weighted average.
- SHGC and VT do not describe condensation at all. They matter for solar control and daylight.
- Air leakage affects drafts and comfort. It is reported separately.
For matching U-factor and SHGC to a project’s climate, see our U-factor and SHGC specification guide. For glass build-ups that raise edge-of-glass temperatures, see our overview of energy-efficient window glazing options.
Why a strong rating does not guarantee a dry window
NFRC is clear that the ratings are guides. Its Condensation Index page notes that actual condensation risk can be influenced by the thermal conductivity of surrounding construction, interior or exterior trim, humidification control, shading and the method of heat distribution on the interior plane of the assembly. It adds that there is no assurance a selected system will not experience condensation.
That is an honest limit, and it shapes how to use the number. Here are the factors outside the label.
Installation and the wall assembly
The label rates the window product, not the opening. If a frame is set in a cold, conductive wall, or insulation stops short of the frame, the perimeter can run colder than the test assumes. Interior trim that boxes in the window or deep returns can trap cold air. Research on window-wall interface details reaches the same conclusion: the rating is determined for a single set of environmental conditions, so it is a comparative measure rather than a prediction of performance in a specific wall.
Good practice at the opening includes continuous air sealing around the frame, insulation that meets the frame and a sill detail that does not shield the glass from room air.
Indoor humidity
A tightly built home with a whole-house humidifier, a spa room, an indoor pool or a kitchen with weak exhaust can push interior relative humidity well above the 30% to 50% range where most windows perform comfortably. The CR scale tests up to 70%, but a home that lives at 60% in January will test any window.
Heat distribution and shading
Heating registers that blow warm air across the glass reduce condensation. Deep window coverings, heavy drapes or blinds that sit tight to the glass cut that airflow and can leave the surface colder. Exterior shading changes surface temperatures as well.
Using CR when you specify windows
NFRC advises builders and designers to use the ratings as guides to choosing fenestration systems while considering the environmental variables that affect risk. Consumer Reports advises homeowners in humid climates who worry about mold to check the optional condensation resistance rating when choosing replacement windows.
A workable process for architects, builders and owners:
- Define the interior conditions. Note the expected winter humidity for each space, including bathrooms, kitchens, wine rooms, pools and nurseries.
- Define the exterior design condition. A project in a mountain or high-desert location will see larger temperature differences than a mild coastal one.
- Request CR or CI for the exact configuration. Ask for the value for the specific frame series, glass package, spacer and operator type, not a generic product family number.
- Confirm the method. Ask whether the number is CR under NFRC 500-2017 or CI under ANSI/NFRC 500-2020.
- Check the limiting component. Ask whether frame, edge-of-glass or center-of-glass set the rating. That tells you where an upgrade would help.
- Coordinate the installation detail. Align the insulation, air barrier and trim with the window plane, and specify the humidity control strategy for the building.
- Pair CR with the other label values. Verify U-factor, SHGC and air leakage, plus design pressure where wind loads apply. Our guide to matching DP ratings to ASCE 7 tests covers that last piece.
Aluminum frames and condensation
Aluminum conducts heat readily, so the thermal break and the edge-of-glass design carry much of the load in a condensation-resistant system. These are the questions to put to any aluminum window supplier. We list them in what to ask suppliers about condensation on aluminum windows: the thermal break construction, the spacer type, the glass package and the test or modeling report behind the rating.
Our perspective
Condensation questions usually arrive late in a project, after the framing is up and the heating plan is set. The better moment is at specification, when the rating, the frame and the wall can still be aligned.
At Viewlux, we build custom aluminum windows and doors through a 26-step production process, and our systems carry NFRC and AAMA certifications. We treat the NFRC label as the shared language between manufacturer, architect, builder and owner. When a project is condensation-sensitive, we recommend naming the exact configuration, frame series, glass package and operator type, and reviewing its label values before the order is placed.
Selling direct from the factory helps here. Specifiers talk to the manufacturer about the configuration itself rather than through several layers of distribution, and that makes sizing, glass and color decisions easier to tie back to the certified product. Custom sizing, multiple glass options and flush or performance sills give a design team the room to match a window to the interior conditions of each space.
Our advice is simple: ask for the numbers, ask what limits them, and detail the installation to protect them.
Liran
Specify condensation-conscious aluminum windows and doors
Viewlux Windows & Doors manufactures custom and factory-direct aluminum systems for residential and commercial projects: casement, sliding, awning, fixed, hung and double-hung windows, plus swing, pivot, bifold, heavy-duty sliding and panoramic sliding doors. Our products are NFRC and AAMA certified, and we offer multiple color and glass options with custom sizing. Showrooms serve California, Colorado and Nevada.

Browse the full Viewlux catalog to find the system that fits your project, or request a quote with your design conditions so the configuration can be reviewed against its label values. If you are comparing operator types, our casement window series is a good place to start.
FAQ
Is a higher condensation resistance rating always better?
Yes, within the same rating method. NFRC states that higher values indicate better resistance to condensation under the specified conditions. The number is comparative, though, so it should be read together with the wall assembly, the climate and the indoor humidity of the building.
Is the CR rating required on an NFRC label?
No. NFRC describes CR as an optional rating that manufacturers can choose to include. If you need it for a humid or very cold project, ask the supplier for the CR or CI value for the specific product configuration you plan to buy.
What is the difference between CR and Condensation Index?
Both are dimensionless ratings from 1 to 100 where higher is better, and both use the same standard 0°F exterior and 70°F interior conditions. CI is the newer method under ANSI/NFRC 500-2020 and is calculated differently from the original CR under NFRC 500-2017. Compare like with like.
Can a window with a good rating still fog or drip?
Yes. NFRC notes there is no assurance that a selected system will avoid condensation. Surrounding construction, trim, humidity control, shading and heat distribution all affect the result, so installation details and indoor humidity management matter as much as the label.
Sources
- Measure Guideline: Energy-Efficient Window Performance and Selection (U.S. Department of Energy, Building America)
- NFRC Condensation Index
- NFRC Condensation Resistance fact sheet
- NFRC Codes and condensation rating information
- How to Make Sense of the NFRC Window Label (Consumer Reports)