In 2026, ENERGY STAR Version 7.0 is still the specification residential windows must meet. It took effect on October 23, 2023, and it sets a maximum U-factor and a solar heat gain coefficient (SHGC) limit for each of four U.S. climate zones. A window that qualifies in Phoenix can fail in Minneapolis, so the zone matters as much as the label. The federal window tax credit has also ended, which changes the financial case for 2026 projects.
This guide covers the Version 7.0 limits, the way certification works, what the ENERGY STAR Most Efficient tier means, and how builders, architects and homeowners should specify windows for 2026 work.
TL;DR
- ENERGY STAR Version 7.0 has applied since October 23, 2023. No newer residential window specification replaces it in 2026.
- Each of the four climate zones has its own U-factor and SHGC limits. Northern and South-Central, for example, ask for opposite things from the glass.
- The federal 25C credit does not apply to windows placed in service after December 31, 2025. Utility and state programs may still reference ENERGY STAR.
- ENERGY STAR checks only U-factor and SHGC. NFRC ratings also report visible transmittance and condensation resistance, so read the whole label.
Table of Contents
- What ENERGY STAR Version 7.0 Requires
- What Changed From Version 6.0
- Which Zone Is Your Project In?
- ENERGY STAR Certified vs. Most Efficient
- ENERGY STAR Is Not the Whole Story: Read the NFRC Label
- The Federal Tax Credit Is Gone for 2026
- What Efficient Windows Can Realistically Deliver
- Specifying Version 7.0 Windows on a Project
- Our Perspective
- Choosing a Supplier for 2026 Projects
- Viewlux Windows and Doors for Energy-Focused Projects
- FAQ
- Sources
What ENERGY STAR Version 7.0 Requires
Version 7.0 was finalized on October 20, 2022 and took effect a year later. Products must carry NFRC-certified U-factor and, where applicable, SHGC ratings that meet the criteria for a given ENERGY STAR climate zone. Ratings must be independently tested, certified and verified under established test procedures.
The prescriptive limits for windows in the final Version 7.0 specification are:
| Climate zone | Maximum U-factor | SHGC |
|---|---|---|
| Northern | 0.22 | 0.17 or higher |
| North-Central | 0.25 | 0.40 or lower |
| South-Central | 0.28 | 0.23 or lower |
| Southern | 0.32 | 0.23 or lower |
EPA reported that the window criteria did not change between the final draft and the final specification, so these figures hold for the published standard. Always confirm against the specification itself before you write numbers into a bid or a drawing set.
How to read the table
U-factor measures how fast heat moves through the whole window. Lower is better. SHGC is the share of solar heat that passes through, on a scale of 0 to 1. The right direction depends on the climate.
- Northern zone: the limit is tight on U-factor, and the SHGC has a floor. In a heating climate, free solar heat in winter is useful, so a very dark low-gain glass can disqualify a window.
- North-Central zone: the SHGC has a cap of 0.40, so the glass must still manage some solar load.
- South-Central and Southern zones: a cap of 0.23 SHGC means a strong low-E coating tuned to block solar gain. The U-factor limits are looser because cooling load, not heat loss, dominates.
The Northern zone also allows a limited trade-off. A slightly higher U-factor is accepted in exchange for a higher SHGC, under the equivalent energy performance path in the specification. Check the current text before relying on it.
For a deeper look at pairing these two numbers with climate, see our guide on matching U-factor and SHGC to your climate.
What Changed From Version 6.0
Version 7.0 lowered U-factor limits in every zone. A trade article on the update notes the North-Central limit dropping from 0.30 to 0.25 and the Southern limit from 0.40 to 0.32. SHGC limits were lowered in the two southern zones, and a minimum SHGC was added for the north.

In practice, the change pushed many products toward better frames, improved spacers and low-E coatings. In the coldest markets, double glazing with a standard frame often struggles to reach 0.22, which is why triple glazing and thermally broken frames appear more often on northern projects.
Which Zone Is Your Project In?
ENERGY STAR assigns zones by county, and the zone map does not follow state lines. A single state can contain two or even three zones. Examples relevant to Viewlux projects:
- California spans several climate conditions. A coastal project and a high-desert project can fall in different zones, so verify by county on the ENERGY STAR zone map.
- Colorado projects in the mountains face a heating-dominated load. Front Range and western slope counties may not share a zone with high-altitude counties.
- Nevada projects, especially in the south, face heavy cooling loads and strong solar exposure.
We do not list county assignments here because they change with the map you use. Look up the exact county on the ENERGY STAR residential windows page before you set targets. Local energy codes, such as California’s Title 24, may set their own limits that differ from ENERGY STAR. A product can satisfy one and not the other, so confirm both.
ENERGY STAR Certified vs. Most Efficient
Standard ENERGY STAR certification means a product meets the baseline criteria for a specific climate region. The Most Efficient designation marks products at the top of the efficiency range. Windows and sliding glass doors are eligible for Most Efficient 2024 recognition, and it is aimed at performance-led projects such as high-end custom homes with demanding envelope targets.
For a spec writer, the practical difference is this. Certification is a pass or fail for a zone. Most Efficient is a signal that the product leads the field. Neither one tells you about daylight, condensation risk or air leakage beyond the limits the program sets, so pair them with the full NFRC label.
ENERGY STAR Is Not the Whole Story: Read the NFRC Label
ENERGY STAR looks at U-factor and SHGC. The NFRC label reports more. It also shows visible transmittance (VT), which governs how much daylight enters, and condensation resistance, which affects comfort and moisture near the glass. Our guide to NFRC window ratings walks through the five numbers worth checking.
On a luxury project with large glass areas, VT and condensation resistance can matter as much as U-factor. A large panoramic opening that technically qualifies but tints the view or fogs on cold mornings will disappoint the owner. Specify all the numbers, not just the one the program rewards.
Check the label by climate zone
Generic claims such as “energy-efficient” mean nothing on a submittal. Look for the Version 7.0 label that matches your project’s zone, because requirements differ widely between northern and southern regions. Ask the supplier for the NFRC Certified Products Directory (CPD) number for each unit and verify the ratings there, not from a brochure.
The Federal Tax Credit Is Gone for 2026
Many pages ranking for this topic still talk about a 30% credit. For windows, that is outdated. The IRS states that the Energy Efficient Home Improvement Credit under section 25C is not allowed for property placed in service after December 31, 2025. The 2025 Form 5695 instructions say the same. ENERGY STAR’s own page lists the window credit as covering products purchased and installed between January 1, 2023, and December 31, 2025.
What this means in practice:
- Windows installed in 2026 do not earn the federal credit. Be wary of marketing that implies they do.
- If you installed qualifying windows in 2025, the credit is claimed for the 2025 tax year. Consult a tax professional about your own return.
- Utility rebates and state or local programs vary by location and may still reference ENERGY STAR. Check with your utility before you buy.
- ENERGY STAR advises keeping the combined ENERGY STAR and NFRC labels from the glass and recording the product details, since programs may request them. Do not peel them off before documenting the CPD number.
Our page on the window tax credit and the documents to keep covers the paperwork side.
What Efficient Windows Can Realistically Deliver
ENERGY STAR reports that replacing single-pane windows with certified windows lowers household energy bills by an average of up to 13 percent nationwide. The program’s messaging also notes that windows take up about 8% of a home’s exterior surface but account for about 45% of heat gain or loss.

Treat those as ranges, not guarantees. Savings depend on the existing windows, the climate, insulation, air sealing and energy prices. A home that already has good double glazing will see less improvement than one with leaky single panes. EPA’s own analysis for the Version 7.0 update estimated payback periods of roughly 8.6 to 11.3 years by zone for the price premium of qualifying windows, as shown in the draft specification. Those are population-weighted estimates and individual projects vary.
For buyers who plan to sell, efficiency also affects marketability. See why energy efficient windows attract buyers and how energy ratings affect resale value.
Specifying Version 7.0 Windows on a Project
A clean specification avoids change orders and failed inspections. Use this sequence.
- Confirm the county’s ENERGY STAR zone and any stricter local code, such as California’s energy standards.
- Write the U-factor and SHGC limits for that zone into the window schedule, with the SHGC direction (floor or cap) stated.
- Require NFRC-certified ratings with the CPD number for every unit type, including the largest sizes. Ratings are tied to specific sizes and configurations.
- Add VT and condensation resistance targets for glazing-heavy elevations.
- Request AAMA performance data for structural and water performance, particularly for tall openings, coastal sites and high-wind areas.
- Coordinate glazing and frame. Low-E coatings, gas fills, warm-edge spacers and thermal breaks work together. See the overview of energy efficient glazing options and the explainer on low-E coatings and IGU design.
- Plan installation. Even a top-rated unit underperforms if flashing, sealing and shimming are wrong. Our installation tips cover the details.
Zero Energy Ready and Passive House
If a project targets a program beyond ENERGY STAR, read that program’s rules separately. The Department of Energy’s Zero Energy Ready Home program, for example, does not currently require ENERGY STAR 7.0 windows and gives builders flexibility in how they reach the envelope target. Passive House work has its own component criteria, discussed in our Passive House window specification guide.
Our Perspective
We build custom aluminum windows and doors, and we sell them direct from the factory. Here is how we think about ENERGY STAR in 2026.
First, the label is a floor, not a design brief. A luxury home with floor-to-ceiling glass faces thermal, acoustic and daylight questions that a two-number program cannot answer. We encourage architects and builders to ask for the full NFRC rating on the exact size and configuration that goes into the wall.
Second, aluminum can meet demanding thermal targets when the system is engineered for it. Thermal breaks, glazing selection and careful profile design do the work. Slim sightlines, large panels and long-term durability are the reasons clients choose aluminum, and performance should not be a trade for them. Our aluminum benefits page explains the material side.
Third, we hold NFRC and AAMA certifications, and our products go through a 26-step production process. We still tell buyers to verify ratings for each product through the NFRC directory and to confirm whether a specific configuration carries ENERGY STAR certification for their zone. Ask for the CPD number, and we will point you to the rating for your configuration.
Fourth, the end of the federal credit puts price back at the center. Selling direct lets us offer factory pricing, with savings of up to 50% compared with traditional dealers, so more of the budget goes into performance rather than distribution margins.
— Liran
Choosing a Supplier for 2026 Projects
Without the credit, the buying decision comes down to documented performance, lead time and total cost. Compare suppliers by type rather than brand:
| Supplier type | Strengths | Points to check |
|---|---|---|
| Local dealer or distributor | Local contact, familiar installers | Dealer margin in the price, limited custom sizes |
| Big-box replacement line | Standard sizes, quick availability | Limited custom shapes, residential-grade frames |
| Factory-direct custom manufacturer | Custom sizing, direct pricing, engineered systems | Lead times, need for installer coordination |
Whatever the supplier, ask for NFRC-certified ratings by CPD number, AAMA test data, the glass package, warranty terms and a written lead time. Our guide to custom aluminum profile configuration options shows what can be tailored.
Viewlux Windows and Doors for Energy-Focused Projects
Viewlux manufactures custom aluminum sliding, casement, awning, fixed and hung windows, plus swing, pivot, bifold, heavy-duty sliding and panoramic sliding doors, and glass railing. Products are NFRC and AAMA certified, available with multiple glass and color options, and sized to the project. Showrooms serve California, Colorado and Nevada.
Browse the full window and door catalog or start with the sliding window line, then request a quote with your climate zone and target U-factor and SHGC. We will respond with the rating data for the configuration you need.
FAQ
Is there an ENERGY STAR windows 2026 update?
Not for residential windows as of October 2026. Version 7.0 remains the governing specification, effective since October 23, 2023. Check the ENERGY STAR page before bidding, since specifications can be revised.
Do I still get a tax credit for ENERGY STAR windows in 2026?
No federal credit applies to windows placed in service after December 31, 2025, according to the IRS. Ask your utility and your state energy office about rebates. Speak with a tax professional about 2025 installations.
Is ENERGY STAR the same as an NFRC rating?
No. ENERGY STAR certification uses NFRC-certified U-factor and SHGC values to decide whether a product qualifies for a zone. The NFRC label reports more, including visible transmittance and condensation resistance, as explained in our NFRC ratings guide.
Can one window qualify in every climate zone?
Sometimes, but not by default. The Northern zone requires an SHGC of at least 0.17, while the South-Central and Southern zones cap it at 0.23, so a product must fall inside both ranges, with a U-factor of 0.22 or lower. Check the certified product listing for the zones a specific product covers.
Why keep the window labels after installation?
Program administrators and inspectors can ask for proof of the product’s ratings. ENERGY STAR advises retaining the labels and recording the CPD number before removing anything from the glass.
Sources
- ENERGY STAR Version 7.0 Residential Windows, Doors, and Skylights
- ENERGY STAR Version 7.0 final draft specification (PDF)
- ENERGY STAR Version 7.0 draft 1 specification (PDF)
- EPA update to the NFRC fall 2022 meeting (PDF)
- ENERGY STAR Residential Windows, Doors, & Skylights
- ENERGY STAR Independently Tested and Certified Energy Performance
- ENERGY STAR Windows Key Messaging 2025 (PDF)
- ENERGY STAR Windows & Skylights Tax Credit
- IRS FAQs on the modification of sections 25C and related credits
- 2025 Instructions for Form 5695 (IRS)
- DOE Efficient New Homes Single Family V2 Policy Record
- Pro Builder: ENERGY STAR V7.0 performance requirements