NFRC window ratings are independent, whole-window performance numbers, covering U-factor, solar heat gain coefficient (SHGC), and visible transmittance (VT), with optional air leakage and condensation resistance figures, that let homeowners compare energy performance, comfort, and daylight across brands. Matching those numbers to your ENERGY STAR climate zone and confirming them in the certified products directory is the fastest way to choose windows that actually perform.
TL;DR:
- The U factor measures performance across the frame and spacer, so compare it alongside SHGC and VT instead of relying on glass center figures.
- Eligibility varies by climate zone: northern homes favor low U factor, southern homes prioritize low SHGC, and central zones should balance both with orientation.
- Record the U factor, SHGC, and VT from the temporary label, then search its CPD ID in NFRC’s directory to verify the manufacturer’s claims.
- Request optional air leakage and condensation resistance scores for drafty or humid rooms; lower leakage and higher resistance can address drafts and interior fogging.
Table of Contents
- What each NFRC metric means for your home
- How to read the NFRC label on your window
- Matching U-factor and SHGC to your climate zone
- Weighing comfort, daylight, and cost tradeoffs
- Why certification matters when you’re sourcing custom windows
- Request NFRC-certified specs on your next quote
- FAQ
- Sources
What each NFRC metric means for your home
Every window carries a set of standardized numbers established by the National Fenestration Rating Council, and each one answers a different question about comfort and energy use.
- U-factor measures how much heat passes through the whole window assembly, not just the glass center. Lower numbers mean better insulation, and because the rating covers frame, spacer, and glazing together, it tends to run higher than a center-of-glass figure alone.
- SHGC describes the fraction of solar heat that gets through the window. A lower SHGC keeps cooling loads down in sunny climates, while a higher SHGC can offset heating costs in colder regions by letting in welcome winter sun.
- Visible transmittance (VT) tells you how much daylight comes through, typically in a range of about 0.30 to 0.70. Coatings that improve U-factor or reduce SHGC often shave off some VT, which is a tradeoff we cover in more detail in our glazing options guide.
- Air leakage (AL) is an optional rating, measured in cubic feet per minute per square foot, and lower numbers mean fewer drafts. Values at or below 0.3 are generally considered tight.
- Condensation resistance (CR) is an optional score from 1 to 100. Higher numbers resist interior condensation better, which matters most in cold climates or humid rooms like kitchens and bathrooms.
These five figures work together. A window with an excellent U-factor but a poor CR score might still fog up on a cold morning, so it pays to look at the full set rather than one number in isolation.
How to read the NFRC label on your window
Every NFRC-rated window ships with two kinds of labels, and knowing the difference saves you from a costly guessing game at install time. The temporary adhesive label, usually stuck to the interior glass, lists the full performance numbers: U-factor, SHGC, VT, and any optional AL or CR ratings. The permanent marking, etched or printed directly onto the frame or spacer, carries an identification code you can use later, even after the sticker is long gone, according to guidance from NFRC on temporary and permanent labels.
- Locate the temporary label on the interior glazing and record the U-factor, SHGC, and VT values.
- Note the Certified Products Directory (CPD) number or product ID printed on the label.
- Visit the NFRC Certified Products Directory and search that ID to confirm the ratings match what the manufacturer quoted.
Pro Tip: If a window has no temporary label at all, treat it as non-certified and ask the seller to provide the CPD ID or lab test reports before you buy.
Matching U-factor and SHGC to your climate zone
ENERGY STAR sets window performance thresholds that vary by U.S. climate zone, and the right numbers for a home in Minnesota look nothing like the right numbers for a home in Arizona. The program’s Version 7.0 specification breaks the country into Northern, North-Central, South-Central, and Southern zones, each with its own U-factor and SHGC targets, and only windows with NFRC-certified values are eligible for evaluation at all.
- In Northern zones, prioritize a low U-factor to hold onto heat; a higher SHGC can help capture passive solar warmth.
- In Southern zones, SHGC matters more than U-factor since keeping solar heat out reduces air conditioning load.
- In North-Central and South-Central zones, balance both figures and factor in orientation, since south and west-facing rooms see far more solar exposure.
- Record the exact U-factor and SHGC from the temporary label, then check the ENERGY STAR product finder to confirm eligibility for your zone.
There is no universal “best” rating. Our breakdown of specific U-factor and SHGC targets by climate walks through example specs, including example cold-climate pairings that illustrate how the two numbers interact.
Weighing comfort, daylight, and cost tradeoffs
Chasing the lowest possible U-factor or SHGC can backfire if it comes at the expense of daylight or budget. Aggressive low-E coatings that push U-factor and SHGC down often reduce VT as well, leaving a room feeling darker than expected, a tradeoff we explore further in our low-E coatings guide.
- On west and southwest exposures in hot climates, prioritize low SHGC to cut afternoon heat gain.
- On south-facing windows in cold climates, favor low U-factor paired with a higher SHGC to capture free solar heat.
- Ask for optional AL and CR ratings in draft-sensitive rooms, coastal homes, or humid climates where condensation on interior glass is a recurring problem.
Pro Tip: If daylight is a priority in a room with large glazing, check the VT number alongside SHGC rather than assuming a low SHGC automatically means a dim room. Our guide on translating VT into room-level specs shows how the two interact.
— Liran
Why certification matters when you’re sourcing custom windows
Independent testing is what makes NFRC numbers trustworthy in the first place. The National Fenestration Rating Council relies on third-party laboratories and standardized test methods, which is why a U-factor on one manufacturer’s label means the same thing as a U-factor on another’s. As a factory-direct manufacturer with NFRC and AAMA certifications, we provide custom window and door systems.
When you request pricing on custom windows, ask for the NFRC numbers and CPD ID in writing before you sign anything. That single step turns a sales conversation into a verifiable spec.
Request NFRC-certified specs on your next quote
Factory-direct sourcing gives you a more transparent path to NFRC-rated performance. Our manufacturing process and certifications support our work on custom aluminum windows and doors. Ask us for product-specific whole-window ratings and pricing.

When you request a quote, ask us for the temporary NFRC label values and CPD ID up front, the same way you would with any certified product. Browse our window and door catalog to see NFRC-rated systems including sliding windows and casement windows, or visit one of our showrooms across California, Colorado, and Nevada before you order.
FAQ
What are the energy ratings for windows?
Window energy ratings come from the National Fenestration Rating Council and cover U-factor, SHGC, and visible transmittance, with optional air leakage and condensation resistance figures. Together they describe how much heat a window loses or gains, how much solar heat it admits, and how much daylight passes through.
What does NFRC stand for and what does it do?
NFRC stands for the National Fenestration Rating Council, an organization that provides independent, third-party testing and whole-window performance ratings for doors, windows, and skylights. It uses standardized test methods so that ratings on different manufacturers’ labels can be compared directly.
What are A+ rated windows?
NFRC ratings use numeric measures such as U-factor, SHGC, and VT rather than an “A+” grade. In the United States, window performance is described using NFRC’s numeric U-factor, SHGC, and VT figures, verified against the Certified Products Directory rather than a letter grade.
How do I know if a window qualifies for ENERGY STAR in my area?
ENERGY STAR eligibility depends on your climate zone, since U-factor and SHGC thresholds differ across the Northern, North-Central, South-Central, and Southern zones. Check the specific NFRC-certified U-factor and SHGC on the window’s label against the current ENERGY STAR criteria for your zone before assuming a product qualifies.
How do I verify that a window’s NFRC rating is accurate?
Look up the product’s CPD ID or label details in the NFRC Certified Products Directory, which lists the officially tested U-factor, SHGC, and VT values. If a window has no temporary label or CPD number, treat its performance claims as unverified until the manufacturer provides documentation.